Objective Fault zones in bedrock are the primary water-controlling structures for water-inrush hazards in underground engineering. The accuracy of groundwater inflow estimation for such zones is directly related to the construction safety of underground engineering. Nevertheless, existing analytical calculation methods suffer from considerable uncertainties.
Methods This study focuses on analytical calculation methods for groundwater inflow into fault zones in tunnel engineering. It systematically reviewed the hydrogeological properties of the ternary structure consisting of fault core, damage zone, and fractured host rock, as well as the attenuation law of permeability with depth. The evolution of analytical methods for groundwater inflow was summarized, ranging from the assumption of homogeneous constant permeability coefficient, depth-varying permeability, to unsteady flow in inclined fault zones and leakage from surrounding rock. The applicable conditions and limitations of existing analytical models were analyzed in depth.
Results The results showed that the permeability of fault zones exhibited lithology-independent ternary structural differentiation and strong heterogeneity. Analytical methods evolved from the assumption of constant hydraulic conductivity to the consideration of depth-dependent attenuation, which explained the peak characteristic that groundwater inflow first increases and then decreases with depth. In the well-flow theoretical framework, unsteady drawdown solutions for inclined fault zones and semi-analytical drawdown solutions considering surrounding rock leakage have been further developed. These solutions can be adopted to estimate water inflow under specified drawdown conditions, but they have not yet incorporated the depth-dependent attenuation law of permeability.
Conclusions Future research should introduce the occurrence of inclined fault zones and hydraulic connections with surrounding rock into analytical calculations of tunnel water inrush. Combined with the depth-dependent attenuation characteristics of differentiated permeability for fault core, damage zone, and fractured host rock, a three-dimensional unsteady multi-factor coupled analytical model should be established. These efforts will help reveal the controlling mechanisms of water inflow in fault zones and improve the reliability of water inflow calculation under complex geological conditions.